11. SECURITY DEPOSIT:
A security deposit in cash or bank guarantee or F.D.R. pledged with the local body at the rate of specified below, shall be payable to the local authority in case of all building applications of apartments/Group Housing/Institutionnal and for commercial buildings in plots above 300 Sq.mtrs.
1) Municipal Corporation Area … Rs. 100/- Sq.M of total built-up area.
2) For UDA Areas excluding Municipal … Rs. 50/- Sq.M of total builtup area.
Corporation Areas
- LIGHTING AND VENTILATION REQUIREMENTS OF BUILDINGS:
1. All buildings and habitable rooms shall have for the admission of light and air, one or more openings, such as windows opening directly onto an exterior space which shall be open to sky. An
interior open space shall not be less than 9 Sq.mtrs. upto height of 12 mtrs. 15 sq.mtrs. upto the height of 18 mtrs. and 25 sq.mtrs. upto the height of above 18 mtrs., subject to minimum of 3 mtrs. in width. No portion of a room shall be assumed to be lighted if it is more than 7.5 metres away from the opening assumed for lighting that portion.
13 MANDATORY INSPECTIONS AND ISSUE OF FIT-FOR OCCUPATION CERTIFICATE BY LOCAL
AUTHORITY:
In respect of commercial complexes/Group Housing and other non-residential complexes, the local authority shall carry out mandatory inspection of the construction at (a) foundation stage (b) Plinth level and at (c) first and upper floor level.
The completed building shall be allowed to be occupied/used only after issue of "Fit for Occupation Certificate" by the local authority on the basis of submission of building completion certificate by architect and owner.
14. HEIGHT OF THE BUILDING:
The maximum permissible height of building shall be as given in the statements on FAR enclosed to this order. In case of multi-storeyed buildings:
- there shall be no restriction on the maximum permissible height of any
Multi-storeyed Buildings subject to multi-storeyed building regulations
And necessary clearance from Fire Services Dept., and National Airport
Authority.
- The minimum extent of site for construction of multi-storeyed building
shall not be less than 1000 Sq.mtrs. in extent and should have the shor
test side not less than 24 mtrs. in width or gain access from a public street
Of a width of not less than 12 mtrs. through a passage of not less than 12
Mtrs.
- Buildings with stilt + 5 floors of 18.0 mtrs. height stands excluded from the
Provisions of multi-storeyed Building Regulations.
|